Concrete pump is an efficient tool for transferring liquid concrete, commonly found in building construction, bridge and tunnel construction, etc. We are dedicated to the design and manufacturing of concrete pumps for many years, and work with numerous customers worldwide to provide them with superior quality products and perfect service. The concrete pump equipment can be powered using electricity or diesel engine to suit different job sites and job requirements. With Aimix expert team, we can help you select the most economical and most appropriate machine for your project.
Types of Concrete Pump For Sale
There are two main types of concrete pumps provided by our group: concrete trailer pump and concrete mixer pump. These pumps can be used directly after arriving at your work site, without the need for installation.
1. Concrete trailer pump
Trailer pump has tires so that it can be towed to the job site by a tractor. The machine has relatively low operating costs, easy maintenance and low maintenance cost.
Models: ABT40C, ABT40D, ABT60C, ABT60D, ABT80C, ABT80D.

Max. theo. concrete output(L./H) | 40/26 m³/h |
Max.concrete pumping pressure(H./L.) | 10/7.6MPa |
Distribution valve type | S Valve |
Diesel engine model | Weifang Delier 6105ZB |
Max. Theoretical Vertical/Horizontal Conveying Distance | 120/500m |
Dimensions:length×width×height | 5000x1850x1700mm |
Total weight | 4500kg |

Max. theo. concrete output(L./H) | 67/45 m³/h |
Max.concrete pumping pressure(H./L.) | 13/7MPa |
Distribution valve type | S Valve |
Diesel engine model | Wechai |
Max. Theoretical Vertical/Horizontal Conveying Distance | 180/800m |
Dimensions:length×width×height | 5800x2000x1750mm |
Total weight | 6500kg |

Max. theo. concrete output(L./H) | 84/45 m³/h |
Max.concrete pumping pressure(H./L.) | 16/11MPa |
Distribution valve type | S Valve |
Diesel engine model | Wechai |
Max. Theoretical Vertical/Horizontal Conveying Distance | 200/800m |
Dimensions:length×width×height | 6300x2100x2350mm |
Total weight | 6900kg |
Features of trailer concrete pump:
- With double pump and double circuit open hydraulic system, the main pump oil path and S valve swing oil path are independent of each other, making the system simple and reliable, and also easy to troubleshoot.
- The advanced S-pipe distribution valve can automatically compensate the wear clearance and has good sealing performance.
- With reverse pump function, it is very easy to resolve pipe blockages in time.
- Adopt wear-resistant alloy spectacle plate and floating cutting ring, which have long service life.
- Automatic centralized lubrication system can ensure effective lubrication during machine operation.
- With remote control, operation is safer and more convenient.
- All parts meet national standard and have good interchangeability.
- The cooling system adopts a forced air-cooling large radiator device to ensure that the working oil temperature of the hydraulic system is controlled below 70 ° C, thereby ensuring that the host hydraulic system is in a normal working condition.
Trailer pump specifications:
ABT40C
Items | Units | Perameters | |
ABT40C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40/26 |
Max.concrete pumping pressure(H./L.) | MPa | 10/7.6 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ180×1200 | |
Hopper capacity x feeding height | L/mm | 400/1100 | |
Outlet diameter | mm | Φ150 | |
Power system | Diesel engine model | Weifang Delier 6105ZB | |
Electrical engineering power | KW | 82 | |
Rotate speed | r/min | 2100 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 5000x1850x1700 | |
Total weight | kg | 4500 |
ABT40D
Items | Units | Perameters | |
ABT40D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ180×1200 | |
Hopper capacity x feeding height | L/mm | 400/1100 | |
Outlet diameter | mm | Φ100 | |
Electrical engineering power | KW | 45 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 28 | |
Mixing system pressure | MPa | 8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 4500x1750x1600 | |
Total weight | kg | 3200 |
ABT60C
Items | Units | Perameters | |
ABT60C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 67/45 |
Max.concrete pumping pressure(H./L.) | MPa | 13/7 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1650 | |
Hopper capacity x feeding height | L/mm | 800/1400 | |
Outlet diameter | mm | Φ180 | |
Power system | Diesel engine model | Wechai | |
Electrical engineering power | KW | 129 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 180/800 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 5800x2000x1750 | |
Total weight | kg | 6500 |
ABT60D
Items | Units | Perameters | |
ABT60D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 60/36 |
Max.concrete pumping pressure(H./L.) | MPa | 13/7 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1650 | |
Hopper capacity x feeding height | L/mm | 800/1100 | |
Outlet diameter | mm | Φ180 | |
Electrical engineering power | KW | 90 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 28 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 560 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 160/800 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 4500x1750x1600 | |
Total weight | kg | 6000 |
ABT80C
Items | Units | Perameters | |
ABT80C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 84/45 |
Max.concrete pumping pressure(H./L.) | MPa | 16/11 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1800 | |
Hopper capacity x feeding height | L/mm | 800/1400 | |
Outlet diameter | mm | Φ180 | |
Power system | Diesel engine model | Wechai | |
Electrical engineering power | KW | 176 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 580 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 200/800 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 6300x2100x2350 | |
Total weight | kg | 6900 |
ABT80D
Items | Units | Perameters | |
ABT80D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 86/45 |
Max.concrete pumping pressure(H./L.) | MPa | 16/11 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1800 | |
Hopper capacity x feeding height | L/mm | 800/1100 | |
Outlet diameter | mm | Φ180 | |
Electrical engineering power | KW | 90 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 14 | |
Capacity of oil tank | L | 580 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 200/800 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 6300x2100x2250 | |
Total weight | kg | 6300 |
2. Concrete mixer and pump
Due to low power consumption, small size, convenient movement, and low cost, concrete mixer pump is ideal for rural towns and new rural construction.
Models: ABJZ30C, ABJZ30D, ABJZ40C, ABJZ40D.

Model | ABJZ40C |
Max. theo. concrete output(L./H) | 40m³ /h |
Mixer rated feed capacity | 0.56m³ |
Mixer rated discharge capacity | 0.45m³ |
Max.concrete pumping pressure(H./L.) | 10MPa |
Diesel engine model | Weichai |
Max. Theoretical Vertical/Horizontal Conveying Distance | 120/500m |
Dimensions:length×width×height | 600x2300x3150mm |
Total weight | 4500kg |

Model | ABJZ40D |
Max. theo. concrete output(L./H) | 40m³ /h |
Mixer rated feed capacity | 0.56m³ |
Mixer rated discharge capacity | 0.45m³ |
Max.concrete pumping pressure(H./L.) | 10MPa |
Electrical engineering power | 45KW |
Max. Theoretical Vertical/Horizontal Conveying Distance | 120/500m |
Dimensions:length×width×height | 4200x2300x3150mm |
Total weight | 4500kg |
Features of concrete mixer pump machine:
- Set mixing and pumping functions in one, which is very convenient for construction and improves work efficiency.
- The mixer delivers large mixing capacity and good mixing effect.
- Integrated design allows the device to occupy a small space, and be flexible and convenient to move.
- The electrical system adopts PLC control with simple operation, stable and reliable performance and high degree of automation.
- Lubrication system adopts automatic control, thus having less fuel consumption, low operating cost and high degree of automation.
- The advanced swing cylinder control system increases the thrust by 50%, which makes the S-tube swing quickly and reliably.
- The main oil pump uses a constant power variable piston pump, which makes full use of the power of the engine.
Concrete mixer pump specifications:
ABJZ30C
Items | Units | Perameters | |
ABJZ30C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 30 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.35 | |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ140×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ150 | |
Winding motor power | KW | Hydraulic motor | |
Stir the motorPower | KW | Hydraulic motor | |
Water pump motor powe | KW | Hydraulic motor | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 37 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 26 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 260 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/300 |
Max. aggregate diameter | mm | Slick/scree:10/20 | |
Inside diameter of delivering pipe | mm | Φ100 | |
Dimensions:length×width×height | mm | 4500x1750x1600 | |
Total weight | kg | 3000 |
ABJZ30D
Items | Units | Perameters | |
ABJZ30D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 30 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.35 | |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ140×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ150 | |
Winding motor power | KW | 5.5 | |
Stir the motorPower | KW | 4.5 | |
Water pump motor powe | KW | 0.55 | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 37 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 26 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 260 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/300 |
Max. aggregate diameter | mm | Slick/scree:10/20 | |
Inside diameter of delivering pipe | mm | Φ100 | |
Dimensions:length×width×height | mm | 4500x1750x1600 | |
Total weight | kg | 3000 |
ABJZ40C
Items | Units | Perameters | |
ABJZ40C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.45 | |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ180×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ150 | |
Winding motor power | KW | Hydraulic motor | |
Stir the motorPower | KW | Hydraulic motor | |
Water pump motor powe | KW | Hydraulic motor | |
Power system | Diesel engine model | Weichai | |
Electrical engineering power | KW | 82 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6 | |
Capacity of oil tank | L | 350 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 600x2300x3150 | |
Total weight | kg | 4500 |
ABJZ40D
Items | Units | Perameters | |
ABJZ40D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.45 | |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ180×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ150 | |
Winding motor power | KW | 5.5 | |
Stir the motorPower | KW | 4.5 | |
Water pump motor powe | KW | 0.55 | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 45 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 26 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 4200x2300x3150 | |
Total weight | kg | 4500 |
ABJS40C with JS500
Items | Units | Perameters | |
ABJS40C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.5 | |
Max.concrete pumping pressure(H./L.) | MPa | 8 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ180 | |
Winding motor power | KW | Hydraulic motor | |
Stir the motorPower | KW | Hydraulic motor | |
Water pump motor powe | KW | Hydraulic motor | |
Power system | Diesel engine model | Weichai | |
Electrical engineering power | KW | 129 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6 | |
Capacity of oil tank | L | 350 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 7500x2300x3150 | |
Total weight | kg | 5000 |
ABJS40D with JS500
Items | Units | Perameters | |
ABJS40D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.5 | |
Max.concrete pumping pressure(H./L.) | MPa | 8 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ180 | |
Winding motor power | KW | 5.5 | |
Stir the motorPower | KW | 18.5 | |
Water pump motor powe | KW | 0.75 | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 45 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 26 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 4200x2300x3150 | |
Total weight | kg | 4500 |
ABJS40C with JS750
Items | Units | Perameters | |
ABJS40C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.75 | |
Max.concrete pumping pressure(H./L.) | MPa | 8 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ180 | |
Winding motor power | KW | Hydraulic motor | |
Stir the motorPower | KW | Hydraulic motor | |
Water pump motor powe | KW | Hydraulic motor | |
Power system | Diesel engine model | Weichai | |
Electrical engineering power | KW | 129 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6 | |
Capacity of oil tank | L | 350 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 7500x2300x3150 | |
Total weight | kg | 5500 |
ABJS40D with JS750
Items | Units | Perameters | |
ABJS40D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.75 | |
Max.concrete pumping pressure(H./L.) | MPa | 8 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ180 | |
Winding motor power | KW | 7.5 | |
Stir the motorPower | KW | 30 | |
Water pump motor powe | KW | 0.75 | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 45 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 28 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 6000x2300x3150 | |
Total weight | kg | 5000 |
Selecting The Right Type Of Concrete Pump For Your Project
Selecting the right concrete pumping equipment is essential to improving your work efficiency and saving cost. In order to specify the right equipment for the job, you need to consider a few things as follows:
- Output capacity
- Pumping distance
- Electric or diesel engine?
- Maximum aggregate particle size
- The engineering situation
- And more
You can discuss these information with one of our experts, who will assist you to select and identify the right type of concrete pump for your application.
Precautions for Using The Concrete Pump Machine
1. What is the function of the one-click repair button?
In normal work, the pump is reversing by the sensor. When the proximity switch is broken or the pipe is blocked, the machine cannot work properly and the concrete may condense in the pipeline. At this time, an emergency device can be used (the one-click repair button is pushed to the on position), which can ensure that the machine works normally until the cleaning is completed.
2. What should you pay attention to about the water tank?
- There must be water in the water tank at work.
- The water in the water tank must not be dirty.
- The water level in the tank should not be too high, which should just pass the piston rod.
3. Maintenance precautions
- There are two grease fittings that need to be filled daily with a grease gun.
- There are large nuts that need to be tightened with a wrench everyday.
- Hydraulic oil needs to be replaced every six months to one year.
- The lithium base grease box – add #00 lithium base grease to the lithium base grease box; do not add dirty oil, otherwise it will block the filter; once the lithium base grease is lower than the filter element, it should be vented first, then refueled.
For more information on Aimix concrete pump, talk to one of our professionals.